No.
Name
(Addr.)
Motor 2 ASR Gain
C5-27
Switching
(35CH)
Frequency
C5-28
Motor 2 ASR
(35DH)
Integral Limit
<10> Default setting is determined by A1-02, Control Method Selection.
<12> Setting range value is dependent on C1-10, Accel/Decel Time Setting Units When C1-10 = 0 (0.01 second units), the setting range becomes
0.00 to 600.00 seconds.
<15> The default setting is determined by E3-01, Motor 2 Control Mode.
<16> Default setting is determined by A1-02, Control Method Selection, and o2-04, Drive Model Selection.
<17> The setting range is 1.00 to 300.0 in CLV.
u d: References
Reference parameters are used to set the various frequency reference values during operation.
No.
Name
(Addr.)
d1-01
Frequency
(280H)
Reference 1
d1-02
Frequency
(281H)
Reference 2
d1-03
Frequency
(282H)
Reference 3
d1-04
Frequency
(283H)
Reference 4
d1-05
Frequency
(284H)
Reference 5
d1-06
Frequency
(285H)
Reference 6
d1-07
Frequency
(286H)
Reference 7
d1-08
Frequency
(287H)
Reference 8
d1-09
Frequency
(288H)
Reference 9
d1-10
Frequency
(28BH)
Reference 10
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
V/f
OLV
Sets the frequency for switching between proportional gain 1, 2 and integral
time 1, 2.
V/f
OLV
Sets the ASR integral upper limit for motor 2 as a percentage of rated load
torque.
d1: Frequency Reference
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
Description
CLV
CLV
common
Description
1.3 Parameter Table
Setting
Default: 0.0 Hz
common
Min: 0.0 Hz
Max: 120.0 Hz
Default: 200%
Min: 0%
Max: 400%
Setting
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
<20>
Page
139
139
Page
140
140
140
140
140
140
140
140
140
140