YASKAWA FSDrive-MV1000 Parameter Manual page 237

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

o4-12: kWh Monitor Initialization
n
The kWh monitors U4-10 and U4-11 are not initialized when the power is shut off or the drive is initialized. Use o4-12 to
manually reset them.
No.
o4-12
kWh Monitor Initialization
Setting 0: No Action
The kWh data are kept as they are.
Setting 1: Reset kWh Data
Resets the kWh counter. The monitors U4-10 and U4-11 will display "0" after they are initialized. When o4-12 is set to 1
and the ENTER key is pressed, kWh data is erased and the display returns to 0.
o4-13: Number of Run Commands Counter Initialization
n
The Run command counter displayed in U4-02 is not reset when the power is cycled or the drive is initialized. Use o4-13
to reset U4-02.
No.
Number of Run Commands Counter
o4-13
Setting 0: No Action
The Run command data are kept.
Setting 1: Number of Run Commands Counter
Resets the Run command counter. The monitor U4-02 will show 0. When o4-13 is set to 1 and the ENTER key is
pressed, the counter value is erased and the setting of the parameter returns to 0.
o4-20: Event Log Initialization
n
Sets the method for initializing event log data.
No.
o4-20
Event Log Initialization
Setting 0: Event log data is retained.
Setting 1: Event log data is initialized (setting returned to 0 after initialization).
o4-21: Trace Initialization
n
Sets the method for initializing trace data.
No.
o4-21
Setting 0: Trace data is retained.
Setting 1: Trace data is initialized (setting returned to 0 after initialization).
u T: Motor Tuning
Auto-Tuning automatically sets and tunes parameters required for optimal motor performance.
For details, refer to the FSDrive-MV1000 Instructions (Manual No. TOEP C710687 02).
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Name
Name
Initialization
Name
Name
Trace Initialization
Setting Range
0, 1
Setting Range
0, 1
Setting Range
0, 1
Setting Range
0, 1
2.10 o: Operator Related Settings
Default
0
Default
0
Default
0
Default
0
237