YASKAWA FSDrive-MV1000 Parameter Manual page 46

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

1.3 Parameter Table
No.
Name
(Addr.)
F6-08
Reset
(36AH)
Communication
Parameters
<3>
F6-30
PROFIBUS-DP
(3CBH)
Node Address
PROFIBUS-DP
F6-31
Clear Mode
(3CCH)
Selection
PROFIBUS-DP
F6-32
Data Format
(3CDH)
Selection
F6-50
DeviceNet MAC
(3C1H)
Address
DeviceNet
F6-51
Communications
(3C2H)
Speed
F6-52
DeviceNet PCA
(3C3H)
Setting
F6-53
DeviceNet PPA
(3C4H)
Setting
DeviceNet Idle
F6-54
Mode Fault
(3C5H)
Detection
F6-55
DeviceNet Baud
(3C6H)
Rate Monitor
F6-56
DeviceNet Speed
(3D7H)
Scaling
F6-57
DeviceNet Current
(3D8H)
Scaling
F6-58
DeviceNet Torque
(3D9H)
Scaling
F6-59
DeviceNet Power
(3DAH)
Scaling
F6-60
DeviceNet Voltage
(3DBH)
Scaling
F6-61
DeviceNet Time
(3DCH)
Scaling
46
All Modes
0: Host controller-related parameters (F6-
the drive is initialized using A1-03.
1: Reset all host controller-related parameters (F6-
drive is initialized using A1-03.
All Modes
Sets the node address.
All Modes
0: Resets drive operation with a Clear Mode command.
1: Maintains the previous operation state when Clear Mode command is
given.
All Modes
0: PPO Type
1: Mode for compatibility with previous products
All Modes
Sets the MAC address.
All Modes
0: 125 kbps
1: 250 kbps
2: 500 kbps
3: Adjustable from network
4: Detect automatically
All Modes
Sets the format of the data set from the DeviceNet master to the drive.
All Modes
Sets the format of the data set from the drive to the DeviceNet master.
All Modes
0: Enabled
1: Disabled, no fault detection
All Modes
Verifies the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
All Modes
Sets the scaling factor for the speed monitor in DeviceNet.
All Modes
Sets the scaling factor for the output current monitor in DeviceNet.
All Modes
Sets the scaling factor for the torque monitor in DeviceNet.
All Modes
Sets the scaling factor for the power monitor in DeviceNet.
All Modes
Sets the scaling factor for the voltage monitor in DeviceNet.
All Modes
Sets the scaling factor for the time monitor in DeviceNet.
Description
/F7-
) are not reset when
/F7-
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Setting
common_
Default: 0
Min: 0
Max: 1
) when the
Default: 0
common_
Min: 0
Max: 125
common_
Default: 0
Min: 0
Max: 1
common_
Default: 0
Min: 0
Max: 1
Default: 0
common_
Min: 0
Max: 64
common_
Default: 0
Min: 0
Max: 4
Default: 21
common_
Min: 0
Max: 255
Default: 71
common_
Min: 0
Max: 255
common_
Default: 0
Min: 0
Max: 1
common_
Default: 0
Min: 0
Max: 2
Default: 0
common_
Min: -15
Max: 15
Default: 0
common_
Min: -15
Max: 15
Default: 0
common_
Min: -15
Max: 15
Default: 0
common_
Min: -15
Max: 15
Default: 0
common_
Min: -15
Max: 15
Default: 0
common_
Min: -15
Max: 15
Page
170

Advertisement

Table of Contents
loading