External Torque Limit - YASKAWA SGDV User Manual

Ac servo drives dc power input design and maintenance
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

5 Operation

5.8.2 External Torque Limit

5.8.2

External Torque Limit

Use this function to limit torque by inputting a signal from the host controller at specific times during machine
operation. For example, some pressure must continually be applied (but not enough to damage the workpiece)
when the robot is holding a workpiece or when a device is stopping on contact.
(1) Input Signals
Use the following input signals to limit a torque by external torque limit.
Type
Input /P-CL
Input /N-CL
Note: Use parameter Pn50B.2 and Pn50B.3 to allocate the /P-CL signal and the /N-CL signal to another terminal. For
details, refer to 3.3.1 Input Signal Allocations.
(2) Related Parameters
Set the following parameters for external torque limit.
Pn402
Pn403
Pn404
Pn405
The setting unit is a percentage of the rated torque.
Note: If the settings of Pn402, Pn403, Pn404, and Pn405 are too low, the torque may be insufficient for acceleration or
deceleration of the servomotor.
5-54
Signal
Connector
Name
Pin Number
ON
(closed)
CN1-26
[Factory setting]
OFF
(open)
ON
(closed)
CN1-12
[Factory setting]
OFF
(open)
Forward Torque Limit
Setting Range
Setting Unit
0 to 800
Reverse Torque Limit
Setting Range
Setting Unit
0 to 800
Forward External Torque Limit
Setting Range
Setting Unit
0 to 800
Reverse External Torque Limit
Setting Range
Setting Unit
0 to 800
Setting
Meaning
Forward external torque limit ON
Forward external torque limit
OFF
Reverse external torque limit ON
Reverse external torque limit
OFF
Factory Setting
1%
800
Factory Setting
1%
800
Factory Setting
1%
100
Factory Setting
1%
100
Limit value
The smaller value of these set-
tings: Pn402 or Pn404
Pn402
The smaller value of these set-
tings: Pn403 or Pn405
Pn403
Speed
Position
Torque
 
 
When Enabled
Immediately
Speed
Position
Torque
 
 
When Enabled
Immediately
Speed
Position
Torque
 
 
When Enabled
Immediately
Speed
Position
Torque
 
 
When Enabled
Immediately
Classification
Setup
Classification
Setup
Classification
Setup
Classification
Setup

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmmvS-v series

Table of Contents