7.12 Write Prohibited Setting (Fn010)

This function prevents changing parameters by mistake and sets restrictions on the execution of the utility
function.
Parameter changes and execution of the utility function become restricted in the following manner when Write
prohibited (P.0001) is assigned to the write prohibited setting parameter (Fn010).
• Parameters: The digital operator cannot be used to change parameters. If attempting to change a parameter,
"NO-OP" will flash on the display and the main menu appears again. Parameters can be
changed from the SigmaWin+.
• Utility Function: Some functions cannot be executed. (Refer to the following table.) If you attempt to exe-
Parameter
No.
Fn000
Alarm history display
Fn002
JOG operation
Fn003
Origin search
Fn004
Program JOG operation
Fn005
Initializing parameter settings
Fn006
Clearing alarm history
Fn008
Absolute encoder multiturn reset and encoder alarm reset
*1
Automatic tuning of analog (speed, torque) reference offset
Fn009
*1
Manual servo tuning of speed reference offset
Fn00A
*1
Manual servo tuning of torque reference offset
Fn00B
Fn00C
Offset adjustment of analog monitor output
Fn00D
Gain adjustment of analog monitor output
Automatic offset-signal adjustment of the motor current detection

Fn00E

signal
Manual offset-signal adjustment of the motor current detection

Fn00F

signal
Fn010
Write prohibited setting
Fn011
Servomotor model display
Fn012
Software version display
Multiturn limit value setting change when a multiturn limit dis-
Fn013
agreement alarm occurs
Fn01B
Vibration detection level initialization
Fn01E
Display of SERVOPACK and servomotor ID
Fn030
Software reset
Fn200
Tuning-less levels setting
Fn201
Advanced autotuning
*2
Advanced autotuning by reference
Fn202
Fn203
One-parameter tuning
Fn204
Anti-resonance control adjustment function
*2
Vibration suppression function
Fn205
Fn206
EasyFFT
Fn207
Online vibration monitor
∗1. This function can be used only with a SERVOPACK for analog voltage references.
∗2. This function can be used only with a SERVOPACK for pulse train references.
cute these utility functions, "NO-OP" will flash on the display and the screen will return to
the main menu.
Function

7.12 Write Prohibited Setting (Fn010)

Write Prohibited
Reference
Setting
Section
Executable
7.2
Cannot be executed
7.3
Cannot be executed
7.4
Cannot be executed
7.5
Cannot be executed
7.6
Cannot be executed
7.7
Cannot be executed
5.9.4
5.3.2
Cannot be executed
5.5.2
Cannot be executed
5.3.2
Cannot be executed
5.5.2
Cannot be executed
7.8
Cannot be executed
7.9
Cannot be executed
7.10
Cannot be executed
7.11
7.12
Executable
7.13
Executable
7.14
Cannot be executed
5.9.7
Cannot be executed
7.15
Executable
7.16
Executable
7.17
Cannot be executed
6.2.2
Cannot be executed
6.3.2
Cannot be executed
6.4.2
Cannot be executed
6.5.2
Cannot be executed
6.6.2
Cannot be executed
6.7.2
Cannot be executed
7.18
Cannot be executed
7.19
7
7-21