YASKAWA SGDV User Manual page 127

Ac servo drives dc power input design and maintenance
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

(3) Related Parameters
Set the internal set speed with Pn301, Pn302, and Pn303.
Internal Set Speed 1
Pn301
Setting Range
0 to 10000
Internal Set Speed 2
Pn302
Setting Range
0 to 10000
Internal Set Speed 3
Pn303
Setting Range
0 to 10000
Note: The maximum speed of the servomotor is used whenever the value which exceeds the maximum speed is set in the
Pn301 to Pn303.
(4) Operating Using an Internal Set Speed
Use ON/OFF combinations of the following input signals to operate with the internal set speeds.
Input Signal
/P-CON
/P-CL
/SPD-D
/SPD-A
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
Setting Unit
Factory Setting
-1
1 min
Setting Unit
Factory Setting
-1
1 min
Setting Unit
Factory Setting
-1
1 min
Motor
Rotation
/N-CL
Direction
/SPD-B
OFF
ON
Forward
ON
OFF
OFF
ON
Reverse
ON
OFF
5.6 Internal Set Speed Control
Speed
When Enabled
100
Immediately
Speed
When Enabled
200
Immediately
Speed
When Enabled
300
Immediately
Speed
Stops at 0 of the internal set speed.
Pn301: Internal Set Speed 1
Pn302: Internal Set Speed 2
Pn303: Internal Set Speed 3
Stops at 0 of the internal set speed.
Pn301: Internal Set Speed 1
Pn302: Internal Set Speed 2
Pn303: Internal Set Speed 3
Classification
Setup
Classification
Setup
Classification
Setup
5
5-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: