YASKAWA SGDV User Manual page 52

Ac servo drives dc power input design and maintenance
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

Step
Display after Operation
Refer to steps 5 to 9 and change the set value of Pn50B from n.6543 to n.6043.
10
Note: If setting Pn50B.2 to 0, the allocation for /P-CL can be changed from CN1-26 to CN1-15.
To enable the change in the setting, restart the SERVOPACK.
11
If the
Key has not been pressed but the
tion mode, any changes that have been made to the parameter will be saved in the SERVOPACK.
<Input signal polarities>
Input signal polarities are as follows when sequence input circuit is connected to a sink circuit. If connected to
a source circuit, polarities are reversed. For details, refer to 3.4.2 Sequence Input Circuit.
Signal
ON
Low (L) level
OFF
High (H) level
(4) Checking Input Signals
Input signal status can be checked using the input signal monitor (Un005). As for the input signal monitor
(Un005), refer to 8.3 Monitoring Input Signals.
Key has been pressed to select another mode such as the utility func-
Level
Voltage Level
0 V
24 V
Keys
Contact
Close
Open
3.3 I/O Signal Allocations
Operation
3-17
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmmvS-v series

Table of Contents