6 Adjustments
6.9.3 Proportional Control
(2) Control Method and Proportional Control Input Signal
Proportional control operation is enabled when the control method is set to speed or position control.
Pn000
Note: Refer to 5.7 Combination of Control Methods for how to switch control methods.
6-62
Parameter
n.
0
Speed control
[Factory setting]
n.
1
Position control
n.
2
Torque control
n.
3
Internal set speed control
n.
4
Internal set speed control
n.
5
Internal set speed control
n.
6
Internal set speed control
n.
9
Torque control
Speed control
n.
A
function
Position control
n.
B
pulse inhibit function
Contents
Speed control
Position control
Torque control
Speed control
Speed control with zero clamp
Position control with reference
Switching to the Proportional
Control
Can be switched with the factory
setting (CN1-16=/P-CON).
/P-CON signal can be allocated to
other terminals as required.
Cannot switch to proportional
control.
Allocation of /P-CON to one of
terminals CN1-12, 15 to 18, 25,
or 26 are needed.