Alarm
Alarm Name
Number
Overspeed of Encoder
A.511
Output Pulse Rate
A.520
Vibration Alarm
A.521
Autotuning Alarm
A.710
Overload: High Load
A.720
Overload: Low Load
A.7A0
Heat Sink Overheated
A.810
Encoder Backup Error
A.820
Encoder Checksum Error
Absolute Encoder Battery
A.830
Error
A.840
Encoder Data Error
A.850
Encoder Overspeed
A.860
Encoder Overheated
*1
Speed Reference A/D Error
A.b10
Speed Reference A/D Data
*1
A.b11
Error
Reference Torque Input Read
*1
A.b20
Error
A.b31
Current Detection Error 1
A.b32
Current Detection Error 2
A.b33
Current Detection Error 3
A.bF0
System Alarm 0
A.bF1
System Alarm 1
A.bF2
System Alarm 2
A.bF3
System Alarm 3
A.bF4
System Alarm 4
A.C10
Servo Overrun Detected
Absolute Encoder Clear Error
A.C80
and Multiturn Limit Setting
Error
Encoder Communications
A.C90
Error
∗1. This alarm will occur only for a SERVOPACK for analog voltage references.
Meaning
The pulse output speed upper limit of the set
encoder output pulse (Pn212) is exceeded.
Incorrect vibration at the motor speed was
detected.
Vibration was detected while performing tun-
ing-less function.
The servomotor was operating for several sec-
onds to several tens of seconds under a torque
largely exceeding ratings.
The servomotor was operating continuously
under a torque exceeding ratings.
The heat sink of the SERVOPACK exceeded
90°C.
The power supplies to the encoder all failed and
position data was lost.
The checksum results of encoder memory is
incorrect.
The battery voltage was lower than the specified
value after the control power supply was turned
ON.
Data in the encoder is incorrect.
The encoder was rotating at high speed when
the power was turned ON.
The internal temperature of encoder is too high.
The A/D converter for speed reference input is
faulty.
A/D conversion data of speed reference input is
incorrect.
The A/D converter for torque reference input is
faulty.
The current detection circuit for phase U is
faulty.
The current detection circuit for phase V is
faulty.
The detection circuit for the current is faulty.
"Internal program error 0" of the SERVOPACK
occurred.
"Internal program error 1" of the SERVOPACK
occurred.
"Internal program error 2" of the SERVOPACK
occurred.
"Internal program error 3" of the SERVOPACK
occurred.
"Internal program error 4" of the SERVOPACK
occurred.
The servomotor ran out of control.
The multiturn for the absolute encoder was not
properly cleared or set.
Communications between the SERVOPACK
and the encoder is not possible.

9.1 Alarm Displays

(cont'd)
Servo-
motor
Alarm
Stopping
Reset
Method
Gr.1
Available
Gr.1
Available
Gr.1
Available
Gr.2
Available
Gr.1
Available
Gr.2
Available
Gr.1
N/A
Gr.1
N/A
Gr.1
Available
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.2
Available
Gr.2
Available
Gr.2
Available
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
Available
Gr.1
N/A
9
Gr.1
N/A
9-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmmvS-v series

Table of Contents