Test Without Motor Function; Motor Information - YASKAWA SGDV User Manual

Ac servo drives dc power input design and maintenance
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

4 Trial Operation

4.6.1 Motor Information

4.6

Test Without Motor Function

The test without a motor is used to check the operation of the host controller and peripheral devices by simu-
lating the operation of the servomotor in the SERVOPACK, i.e., without actually operating a servomotor. This
function enables you to check wiring, verify the system while debugging, and verify parameters, thus shorten-
ing the time required for setup work and preventing damage to the machine that may result from possible mal-
functions. The operation of the motor can be checked during performing this function regardless of whether
the motor is actually connected or not.
Use Pn00C.0 to enable or disable the test without a motor.
Pn00C
4.6.1

Motor Information

The motor information that is used for a test without a motor is given below.
(1) Motor Connected
If a motor is connected, the information from the connected motor is used for the motor and encoder informa-
tion. The set values of Pn00C.1 and Pn00C.2 are not used.
(2) Motor Not Connected
The virtual motor information that is stored in the SERVOPACK is used. The set values of Pn00C.1 and
Pn00C.2 are used for the encoder information.
Encoder Resolution
The encoder information for the motor is set in Pn00C.1.
Pn00C
Encoder Type
The encoder information for the motor is set in Pn00C.2.
Pn00C
4-12
SERVOPACK
Reference
Host controller
Response
Parameter
n.
0
Disables the test without a motor.
[Factory setting]
Enables the test without a motor.
n.
1
Parameter
n.
Sets 13 bits as encoder resolution for the test without a
0
motor.
[Factory setting]
Sets 20 bits as encoder resolution for the test without a
n.
1
motor.
Parameter
n. 0
Sets an incremental encoder as encoder type for the test
without a motor.
[Factory setting]
Sets an absolute encoder as encoder type for the test
n. 1
without a motor.
Simulates the operation
Reference
without motor.
Response
Meaning
Meaning
Meaning
Analog
When
Classification
Enabled
After restart
Setup
When
Classification
Enabled
After restart
Setup
When
Classification
Enabled
After restart
Setup

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmmvS-v series

Table of Contents