Parameter
Size
No.
Application Function Select
2
Switch 9
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn009
Application Function Select
2
Switch B
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00B
Setting
Name
Range
0000 to 0111
Reserved (Do not change.)
Current Control Method Selection
0
Current control method 1
1
Current control method 2
Speed Detection Method Selection
0
Speed detection 1
1
Speed detection 2
Reserved (Do not change.)
0000 to 1111
Parameter Display Selection
0
Setup parameters
1
All parameters
Alarm Gr.2 Stop Method Selection
0
Stops the motor by setting the speed reference to "0".
1
Stops the motor by coasting.
Reserved (Do not change.)
Reserved (Do not change.)
Factory
When
Units
Setting
Enabled
0010
After restart
0000
After restart