Step
Display after Operation
9
10
11
12
Note: The status display will always be RUN when the servomotor power is ON.
Keys
If readjustment is required, select the digit with the
or
Key or change the LEVEL with the
or
Key. Check the response.
If readjustment is not required, go to step 10.
Note: The higher the level, the greater the respon-
siveness will be. If the value is too large, how-
ever, vibration will occur.
• If vibration occurs, press the
VOPACK will automatically detect the vibration
frequencies and make notch filter or an anti-reso-
nance control settings. When the notch filter is set,
"NF1" or "NF2" will be displayed on the bottom
row. When the anti-resonance control is set,
"ARES" will be displayed in the lower right corner.
• If the vibration is great, the vibration frequency
will be detected automatically even if the
is not pressed and a notch filter or an anti-reso-
nance control will be set.
Press the
Key. A confirmation screen will be dis-
played after LEVEL adjustment.
• Press the
After the data is saved, "DONE" will flash for
approximately two seconds and then "RUN" will
be displayed.
• To return to the previous value, press the
• Press the
saving the values.
Press the
Key to complete the one-parameter
tuning operation. The screen in step 2 will appear
again.