YASKAWA SGDV User Manual page 23

Ac servo drives dc power input design and maintenance
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

Encoder Output Pulse
Input
Sequence
Signals
Input
which can
be allocated
I/O
Signals
I/O
Signals
Fixed Output Servo alarm (ALM)
Output
Sequence
Signals
Output
which can
be allocated
Digital Operator
Communi-
cations
Function
Personal Computer
Communications (USB)
LED Display
Analog Monitor
Dynamic Brake (DB)
Regenerative Processing
Overtravel Prevention (OT)
Protective Function
Utility Function
Speed regulation by load regulation is defined as follows:
No-load motor speed
Speed regulation
=
Phase A, B, C: line driver
Encoder output pulse: any setting ratio (Refer to 5.3.7.)
Number of
7 ch
Channels
• Servo ON (/S-ON)
• Proportional control (/P-CON)
• Forward run prohibited (P-OT), reverse run prohibited
(N-OT)
• Alarm reset (/ALM-RST)
• Forward external torque limit (/P-CL), reverse external
torque limit (/N-CL)
• Internal set speed selection (/SPD-D, /SPD-A, /SPD-B)
Functions
• Control selection (/C-SEL)
• SEN signal (/SEN)
• Zero clamping (/ZCLAMP)
• Reference pulse inhibit (/INHIBIT)
• Gain selection (/G-SEL)
• Reference pulse input multiplication switching
(/PSEL)
Signal allocations can be performed, and positive and
negative logic can be changed.
Number of
3 ch
Channels
• Positioning completion (/COIN)
• Speed coincidence detection (/V-CMP)
• Rotation detection (/TGON)
• Servo ready (/S-RDY)
• Torque limit detection (/CLT)
• Speed limit detection (/VLT)
Functions
• Brake (/BK)
• Warning (/WARN)
• Near (/NEAR)
• Reference pulse input multiplication switching output
(/PSELA)
Signal allocations can be performed, and positive and
negative logic can be changed.
Connect the Σ-V digital operator (model: JUSP-OP05A-1-E) through an
applicable analog monitor unit (model: JUSP-PC001-E) and a connection
cable (model: JZSP-CF1S05-A3-E), or a relay cable (model: JZSP-CF1S00-
A3-E).
Supports SigmaWin+.
Based on the USB 1.1 standard (12 Mbps).
ALM (red), RDY (green)
Number of points: 2
±
Output voltage:
10 VDC (linearity effective range
Output through the analog monitor unit (model: JUSP-PC001-E), the connec-
tion cable (model: JZSP-CF1S05-A3-E), and the analog monitor cable
(model: JZSP-CA01-E).
Not supported.
Not supported.
Deceleration to a stop or free run to a stop at P-OT or N-OT
Overcurrent, overvoltage, overload, and so on.
Gain adjustment, alarm history, JOG operation, origin search, and so on.
-
Total load motor speed
Rated motor speed
1.3 SERVOPACK Ratings and Specifications
±
8 V)
Analog
×
100%
(cont'd)
1
1-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmmvS-v series

Table of Contents