10.2.2 Parameters
Parameter
Size
No.
Application Function Select
2
Switch 7
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn007
Application Function Select
2
Switch 8
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn008
10-8
Setting
Name
Range
0000 to 005F
Analog Monitor 2 Signal Selection
00
Motor rotating speed (1 V / 1000 min
01
Speed reference (1 V / 1000 min
02
Torque reference (1 V/100% rated torque)
03
Position error (0.05 V/1 reference unit)
04
Position amplifier error (after electronic gears) (0.05 V/ 1 encoder pulse unit)
05
Position reference speed (1 V / 1000 min
06
Reserved (Do not change.)
07
Reserved (Do not change.)
08
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
09
Reserved (Do not change.)
0A
Torque feedforward (1 V/100% rated torque)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C
Completion of position reference (completed: 5 V not completed: 0 V)
0D
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
0000 to 7121
Lowered Battery Voltage Alarm/Warning Selection
0
Outputs alarm (A.830) for lowered battery voltage.
1
Outputs warning (A.930) for lowered battery voltage.
Reserved (Do not change.)
Reserved (Do not change.)
Warning Detection Selection
0
Detects warning.
1
Does not detect warning.
Factory
When
Units
Setting
Enabled
0000
Immediately
-1
)
-1
)
-1
)
0000
After restart
(cont'd)
Reference
Classification
Section
Setup
6.1.3
Setup
Reference
Section
5.9.3
Reference
Section
9.2.1

Hide quick links: