b. Copy the main storage dump to removable media (see Working with Storage Dumps in the
(TM)
iSeries
Service Functions
c. Provide your next level of support with this information.
This ends the procedure.
v Yes: Use the SRC information from the original failure and return to System Reference Codes.
Analyze the problem using the data in characters 9-16 of the bottom 16 character line of function
13 (word 9) on the Problem Summary Form in place of word 1.
This ends the procedure.

Logical partition (LPAR) PIP

For use by authorized service providers.
Use this page to identify logical partition (LPAR) configuration conditions and the associated corrective
actions.
LPAR-PIP01: Use this procedure to identify Logical Partition (LPAR) configuration conditions and their
associated corrective actions.
1. Is there only one B6005311 error logged, and is it against the load source device for the partition, in
either the Primary or a secondary partition?
v Yes: Is the reporting partition the Primary partition?
– Yes: Continue with the next step.
– No: Go to step 3 (See page 144).
v No: Go to step 4 (See page 144).
2. Was the load source disk unit migrated from another partition within the same system?
v Yes: Is this load source device intended to be the load source for the Primary partition?
– Yes: To accept the load source disk unit: Go to SST/DST in the current partition and select
Work with system partitions—>Recover configuration data—>Accept load source disk
unit.
This ends the procedure.
– No: Power off the system. Return the original load source disk to the Primary partition and
perform a system IPL.
This ends the procedure.
v No: The load source disk unit has not changed. Contact your next level of support.
This ends the procedure.
3. The reporting partition is a secondary partition.
Since the last IPL of the reporting partition, have one of the following occurred?
v Has the Primary partition time/date been moved backward to a time/date earlier than the previous
setting?
v Has the system serial number been changed?
v Was the load source disk unit in this secondary partition, replaced intentionally with a load source
from another system or another partition from the same system?
v Yes: To accept the load source disk unit: Go to SST/DST in the current partition and select Work
with system partitions—>Recover configuration data—>Accept load source disk unit
This ends the procedure.
v No: Contact your next level of support.
This ends the procedure.
4. Are there multiple B600 5311 SRCs logged in the same partition?
v Yes: Continue with the next step.
v No: None of the conditions in this procedure have been met, call your next level of support.
This ends the procedure.
144
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
information).