IBM iSeries Series Hardware Problem Analysis And Isolation page 36

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

5. Perform the following:
a. Dial the telephone number for the system.
b. Wait at least two minutes for the system to answer.
Note: The Ring Indicator signal is used to start the remote IPL. If the caller hangs up the telephone
before the system disconnects the line (indicated by the return of the dial tone), the IPL will not
complete. The caller may hear other tones before the dial tone.
Was the telephone answered in two minutes?
v Yes: Does the IPL complete successfully?
– No: Continue with the next step.
– Yes: This ends the procedure.
v No: Continue with the next step.
6. The IPL from a remote location was not successful. The following steps show you how to start a
manual IPL and how to analyze the remote IPL problem.
Select Manual or Normal mode on the control panel.
Note: If you want the Use Dedicated Service Tools (DST) display shown after the IPL, select Manual
mode on the control panel.
Start an IPL by powering on the system (see Power on/off the system and logical partitions).
Does the IPL complete successfully?
v Yes: Continue with the next step.
v No: Go to "Starting point for all problems" on page 2.
This ends the procedure.
7. Did you verify that the operating system has the correct value of 1 for the remote power-on function
in step 2 (See page 23)?
v No: Continue with the next step.
v Yes: Go to step 9 (See page 24).
8. On the command line, enter the Display System Value command:
DSPSYSVAL QRMTIPL
Does the operating system have the correct value of 1 for the remote power-on function?
Figure 5. Example of remote power-on configuration display for QRMTIPL
+------------------------------------------------------------------------------+
|Display System Value
|System: S0000000
|System value . . . . . . . . . : QRMTIPL
|Description . . . . . . . . . : Remote power on and IPL
|Value . . . . . . . . . . . . :
|1 = Allowed
+------------------------------------------------------------------------------+
v Yes: Continue with the next step.
v No: Perform the following:
a. Change the value to 1 by entering the Change System Value command (CHGSYSVAL QRMTIPL)
on the command line.
b. Power off the system by entering the Power Down System Immediate command (PWRDWNSYS
*IMMED) on the command line.
c. Select Normal mode on the control panel.
d. Verify that an IPL from a remote location completes successfully by going to step 5 (See page
24).
9. Start the communications verification function and run a cable wrap test on the suspected cable by
doing the following:
a. Enter the Verify Communications command (VFYCMN) on the command line to show the
communications verification display.
24
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and Isolation
0 = Not allowed
|
|
|
|
|
|

Advertisement

Table of Contents
loading

Table of Contents