Mappwr - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

3. Record the bus number value, BBBB, of the IOP or IOA Direct Select Address. See SRC address
formats. Search for the bus number in HSM or the System Configuration Listing to determine which
frame or I/O tower contains the failing component. Record the frame or tower type.
4. The failing component is the FRU containing the multi-adapter bridge. Identify the system model,
tower, expansion unit, or machine type that is indicated by the location in the SAL, or by using the bus
number, BBBB. Using the information provided in the table below, exchange the FRU that is indicated.
Table 1. FRU containing the multi-adapter bridge
System model, tower,
expansion unit or
machine type
Model 270
Record the processor
feature code (characters 5
through 8 of function 20 on
the control panel)
Models 800 and 810
Model 820
Model 825
Models 830 and SB2 base
I/O tower (FC 9074)
Models 840 and SB3 Base
I/O Tower (FC 9079)
Models 870 and 890
FC 5074 Expansion I/O
Tower
FC 5075 Expansion I/O
Tower
FC 5078, 0578 expansion
I/O unit
FC 5079 (1.8m expansion
tower)
FC 5088, FC 0588 PCI
Expansion Unit
FC 5095, FC 0595 PCI
Expansion Tower
External xSeries Server
This ends the procedure.

MAPPWR

For use by authorized service providers.
Use this procedure to help locate power problems in the processor subsystem, I/O subsystems, or rack. If
a problem is detected, this procedure helps you isolate the problem to a failing unit. Observe the following
safety notices during service procedures.
DANGER
An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or
the products that attach to the system. It is the customer's responsibility to ensure that the outlet is
correctly wired and grounded to prevent an electrical shock. (RSFTD201)
364
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
Name of FRU to
exchange
System unit backplane
System unit backplane
System unit backplane
System unit backplane
Tower card
Tower card
Tower card
Tower card
Tower card
Tower card
Tower card
Tower card
Tower card
Integrated xSeries Adapter
Card
FRU
Link to failing component service
position
information (CCIN, locations diagram,
remove and replace procedure).
MB1
Use the Model 270 diagrams and tables by
processor feature code and follow the
Locations diagram link or the FRU positions
and failing components link for the processor
feature code.
MB1
See Locations — Models 800 and 810
MB1
See Locations — Model 820
CB1
See Locations — Model 825
CB1
See Locations — Models 830, SB2 system
unit with FC 9074 base I/O tower.
CB1
See Locations for FC 9079 Base I/O Tower
(On Models 840, SB3 system unit).
CB1
See Locations — Models 870 and 890.
CB1
See Locations — FC 5074 I/O Tower.
CB1
See Locations — FC 5075 I/O tower.
CB1
See Locations — FC 5078, 0578 Expansion
I/O Unit.
CB1
See Locations — FC 5079 I/O tower.
CB1
See Locations — FC 5088, FC 0588
Expansion I/O Tower.
CB1
See Locations — FC 5095, FC 0595
Expansion I/O Tower.
Follow the
See Locations — Integrated xSeries Adapter
HSL cables.
Card (IXA).

Advertisement

Table of Contents
loading

Table of Contents