Sdiop-Pip28 - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

4. See Locations and addresses and find the diagram of the system unit, or the expansion unit. Find the
card slot that is identified by the I/O card direct select address (DSA) and unit address. If there is no
IOA with a matching DSA and unit address, the IOP and IOA are one card. Use the IOP with the
same DSA.
5. Choose from the following options:
v If the devices from step 3 (See page 206) of this procedure have never been installed on this
system, go to step 6 (See page 207).
v If the devices are not in the current system disk configuration, go to step 8 (See page 207).
v Otherwise, the devices are part of the system disk configuration; go to step 10 (See page 207).
6. Choose from the following options:
v If this I/O card and cache card were moved from a different system, continue with the next step.
v Otherwise, the cache card was shipped to the customer without first being cleared. Perform the
following:
a. Make a note of the serial number, the customer number, and the device types and their serial
numbers. These were found in step 3 (See page 206).
b. Inform your next level of support.
c. Then, go to step 9 (See page 207) to clear the cache card and correct the URC 9051 problem.
7. Install both the I/O card and the cache cards back into their original locations. Then re-IPL the
system. There could be data in the cache card for devices in the disk configuration of the original
system. After an IPL to DST and a normal power off on the original system, the cache card will be
cleared. It is then safe to move the I/O card and the cache card to another location.
8. One or more devices that are not currently part of the system disk configuration were installed on this
I/O card. Either they were removed concurrently, they were removed after an abnormal power off, or
they have failed. Continue with the next step.
9. Use the Reclaim IOP cache storage procedure to clear data from the cache for the missing or failed
devices as follows:
a. Perform an IPL to DST. See Performing an IPL to DST in the iSeries Service Functions
information.
If you cannot perform a type A or B IPL, perform a type D IPL from removable media.
b. Reclaim the cache adapter card storage. See Reclaim IOP cache storage.
10. Choose from the following options:
v If this I/O card and cache card were moved from a different location on this system, go to step 7
(See page 207).
v If the devices from step 3 (See page 206) of this procedure are now installed on another I/O card,
and they were moved there before the devices were added to the system disk configuration, go to
step 6 (See page 207). (On an MES, the disk units are sometimes moved from one I/O card to
another I/O card. This problem will result if manufacturing did not clear the cache card before
shipping the MES.)
v Otherwise, continue with the next step.
11. One or more devices that are currently part of the system disk configuration are either missing or
failed, and have data in the cache card. Consider the following:
v The problem may be because devices were moved from the I/O card concurrently, or they were
removed after an abnormal power off. If this is the case, locate the devices, power off the system
and install the devices on the correct I/O card.
v If no devices were moved, look for other errors logged against the device, or against the I/O card
that occurred at approximately the same time as this error. Continue the service action by using
these system reference codes.
SDIOP-PIP28: For use by authorized service providers.
Analyze hardware problems
207