SP-PIP44: Use this procedure if you have a B1xx 4682 SRC detected on a Model 825.
1. Locate the Extended Reference Code in characters 9 through 12 of the top 16 characters of Function
12:
12 xxxxxxxxEEEExxxx
xxxxxxxxxxxxxxxx
2. Use the following table to find the recommended service action.
Table 1. Recommended service action for B1xx 4682 SRC on a Model 825
Value for EEEE:
Recommended service action:
804B
1. Replace the control panel (see symbolic FRU "CTLPNL" on page 323).
2. Then, IPL the system.
3. If the same error occurs again, replace the backplane (see symbolic FRU "BACKPLN" on
page 284).
804C
v If a card is located in position C09:
1. Power off the system and reseat the card.
2. Then, IPL the system.
3. If the same error occurs again, replace the card in C09 (see Locations - Model 825
4. Then, IPL the system.
5. If the same error occurs again, replace the backplane (see symbolic FRU "BACKPLN" on
v If a card is not located in position C09, replace the backplane (see symbolic FRU "BACKPLN"
on page 284).
804D
1. Replace the control panel (see symbolic FRU "CTLPNL" on page 323).
2. Then, IPL the system.
3. If the same error occurs again, replace the backplane (see symbolic FRU "BACKPLN" on
page 284).
This ends the procedure.
SP-PIP45: For use by authorized service providers.
This procedure is for IPL failures that terminate with SRC B1XX4604.
220
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
Value for AAAAAAAA
********
page 284).
Recommended Service Action:
Load source device not found during
main storage dump.
The service processor is directed to
use the load source device during
main storage dump, but no load
source is found at the device address
being used, or the device is not
accessible by the service processor.
The DSA of the load source IOP is in
IIIIIIII (word 7). The device unit
address is DDDDDDDD (word 8).
Verify the IOP DSA and device unit
address are correct for the location of
the load-source on this system.