Failing item code
Description/Action
FI00880
FI00880 indicates that a terminating plug on the device bus to this IOP is the failing item.
Note: If the unit is a 9427, an internal terminating plug is used (see the service information
for the specific device).
The following list shows the possible failing items:
v Terminating plug for 2440 Tape Unit — part 79X3795
v Terminating plug for 3490, 3570, 3590, and 7208 Model 342 Tape Units — part 61G8324
v SCSI differential terminating plug for 3995 iSeries
v SCSI single-ended terminating plug for 3995 iSeries
v Terminator for 637x, 638x, and 6390 Tape Units — Terminator is part of the DASD
v Terminating plug for 63A0 Tape Unit — See device documentation.
v Terminating plug for 7208 Model 002 Tape Drive — part 91F0721
v Terminating plug for 7208 Model 012 Tape Drive — part 46G2599
v Terminating plug for 7208 Model 222 Tape Drive — part 46G2599
v Terminating plug for 7208 Model 232 Tape Drive — part 79X3795
v Terminating plug for 7208 Model 234 Tape Drive — part 79X3795
v Terminating plug for 9348 Tape Unit — part 79X3795
FI00882
FI00882 indicates that the addressed unit is the failing item.
Determine the address and type of the failing unit (see System Reference Code (SRC)
Information in the iSeries
If one of the following device types is the failing item, see the service information for the
device Model installed on the system: * 2440 * 3490 * 3570 * 3590 * 3995 * 63A0 * 7208 *
9347* 9348 * 9427.
If the tape unit being used is in the FC 5032 Removable Storage Unit, the failing item is the
636x Tape Unit.
See "Removable Storage Unit (FC 5032)" in the SY44-4934-00, FC 504x Problem Analysis
and Repair and Parts information.
Note: The FC 5032 DSE module connects tape units as follows:
v Tape units in the top 5032 locations (positions 1 and 2) use the top external cable
v Tape units in the bottom 5032 locations (positions 3 and 4) use the bottom external cable
A tape unit to the left or right of the tape unit being used (in position 1 or 2 or in position 3
or 4) may be causing the failure.
A tape unit above or below the tape unit being used is not a probable cause of the failure
because it is attached to a different internal FC 5032 DSE I/O bus and, as described above,
uses the other external signal cable.
FI00883
FI00883 indicates that a unit attached to the same IOP, other than the addressed unit
identified by FI00882 (See page 264), is the failing item.
FI00884
FI00884 indicates that any unit attached to the IOP may be the failing item.
See FI00882 (See page 264) for the list of possible units.
264
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
79X3795
Models C4x — part 34H5608
backplane. Use the IOA type and see the symbolic FRU DEVTERM to determine the
correct part.
(TM)
Service Functions
connector.
connector.
(TM)
Optical Library Dataserver — part
(TM)
Optical Library Dataserver
information).