Cblpwr - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

– 6.0 meters - part 21F9469
– 15.0 meters - part 21F9358
– 30.0 meters - part 21F9359
– 60.0 meters - part 21F9360
– 100.0 meters (SPCN optical cable) - part 21F9415
– SPCN optical adapter - part 90H6287
– SPCN port cable (frame-to-node) - part 21F9362
– Frame-to-frame cable - part 87G6235
– Integrated xSeries
12. Is the SRC 1xxx-2613?
v No: Continue with the next step.
v Yes: Go to Determine line cord, plug, and receptacle type in the Plan for hardware and software
topic in Information Center, to determine the power cable part number for systems in your country
or region. This information is also available in the Plan for hardware and software
the Power topic.
13. Is the SRC 1xxx-8940, 8941, 8942 or 8943?
v Yes: Continue with the next step.
v No: Go to "Starting point for all problems" on page 2.
This ends the procedure.
14. Reseat the RS485 cable. Does this correct the problem?
Note: It may take up to one minute for the frame ID to stop blinking.
v Yes: This ends the procedure.
v No: Continue with the next step.
15. Exchange the RS485 cable assembly part - 21P4162. Does this correct the problem?
Note: It may take up to one minute for the frame ID to stop blinking.
v Yes: This ends the procedure.
v No: Go to the next FRU in the list.
This ends the procedure.

CBLPWR

For use by authorized service providers.
A power or AC line cord may be the failing item.
Use the diagram below to view the power cable locations, in conjunction with the tables below that give
more details. The tables include:
v Power cables (See page 302)
v AC line cords (See page 303)
Figure 1. Part locations for power cables
(TM)
Server SPCN-Y cable assembly - part 04N2652
book under
Analyze hardware problems
301

Advertisement

Table of Contents
loading

Table of Contents