IBM iSeries Series Hardware Problem Analysis And Isolation page 263

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

Failing item code
Description/Action
FI00090
FI00090 indicates that the removable media device for an alternate IPL is the failing item.
Note: Determine if the system has logical partitions. Go to Determine if the system has
logical partitions before continuing with this procedure.
Determine the device that is failing by doing the following:
1. Select function 01 (Select IPL) on the control panel and press Enter to verify that the
2. Use the service information for the specific removable media unit for an alternate IPL to
FI00092
FI00092 indicates that the load-source for an alternate IPL or the interface to the
load-source is the failing item.
Note: Determine if the system has logical partitions. Go to Determine if the system has
logical partitions, before continuing with this procedure.
Note: If the load source is an optical unit, you may need to perform function 3 to IPL the
system again. This will make the unit ready.
To locate the alternate load-source for a system that does not have multiple partitions see
Determine the load source disk and alternate IPL device. To locate the alternate load-source
for the Primary partition on a system that has multiple partitions, or locate the alternate IPL
load-source for a secondary partition see >iSeries
Use the device type to determine the part.
FI00096
FI00096 indicates that the IOP attached to the load-source device is the failing item.
Note: Determine if the system has logical partitions. Go to Determine if the system has
logical partitions, before continuing with this procedure.
1. Verify that the IPL type is correct:
2. The failing CFIOP or IOP may have a removable storage I/O adapter FRU. Replace the
active IPL type is D.
Note: Use the system configuration list to identify the device (see Hardware Service
(TM)
Manager in the iSeries
The possible failing devices are the following type numbers: 3490, 3570, 3590, 632x,
6382, 6383, 6386, 6387, 63A0, 7208, 9348, and 9427.
analyze the device failure.
v For a failing logical partition, other than the Primary partition, on systems with multiple
logical partitions, go to the "Work with partition status" screen and determine the
active IPL type (source).
v For a failing Primary partition or for systems with only one partition select function 01
(Select IPL) on the control panel to display the active IPL type. Select function 01 on
the control panel and press Enter to display the present IPL mode.
storage IOA first using the STORIOA symbolic FRU. To locate the load source for a
system that does not have multiple partitions see Determine the load source disk and
alternate IPL device. To locate the load source for the Primary partition on a system that
has multiple partitions see Determine the load source disk and alternate IPL device. To
locate the load source for a secondary partition, see Locating the secondary partition's
(TM)
load source in the iSeries
Service Functions
information).
(TM)
Service Functions
Service Functions
.
information.
Analyze hardware problems