SLOTERR

For use by authorized service providers.
SLOTERR: card slot control hardware detected an error.
The multi-adapter bridge detected a problem with a card location that it controls. The problem is in the
controls for the card slot. The card location may or may not have an installed card. If there is a card
installed in that location, it may be the source of the problem.
Note: If there is a Linux partition in the system, any IOPs plugged into slots owned by a Linux partition will
not power on. This error will be logged. Correct the situation by removing the IOP cards.
1. Is there a single card position listed in the SAL for this failing item?
v No: Continue with the next step.
v Yes: Go to step 5 (See page 462).
2. Is there a range of card positions (PCI Bridge Set) listed in the SAL for this failing item?
v No: Continue with the next step.
v Yes: LIC could not identify the slot with the error. Perform "Bus PIP MAB-03" on page 95 to
determine the card position with the failure.
This ends the procedure.
3. Record the Direct Select Address (DSA) which is word 7 of the SRC from the SAL display.
4. Examine the muti-adapter bridge function number in the DSA. See "DSA breakdown" on page 63 in the
Bus PIP Overview page.
Is the multi-adapter bridge function number less than or equal to 7?
v Yes: Go to "Bus PIP PCIBUS-PIP1" on page 99. Return here after locating the card.
v No: LIC could not identify the slot with the error. Perform "Bus PIP MAB-03" on page 95 to
determine the card position with the failure.
This ends the procedure.
5. Does the SRC that sent you here appear more than once, OR does any other SRC with this symbolic
FRU appear from the same IPL AND against the same resource?
v Yes: The failure is at the multi-adapter bridge. Do not use this symbolic FRU. Go to the next failing
item in the list.
This ends the procedure.
v No: Locate the message in the following table to determine the problem and the corrective action.
462
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation