Sdiop-Pip22; Sdiop-Pip23; Sdiop-Pip25 - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

Have you determined the location of the I/O card and disk unit that is causing the problem?
v Yes: Exchange the disk unit that is causing the problem. See Start disk service here.
This ends the procedure.
v No: Ask your next level of support for assistance.
This ends the procedure.
SDIOP-PIP22: For use by authorized service providers.
1. If the system has logical partitions, perform this procedure from the logical partition that reported the
problem. To determine if the system has logical partitions, go to Determine if the system has logical
partitions, before continuing with this procedure.
2. Access SST/DST by doing one of the following:
v If you can enter a command at the console, access system service tools (SST) (see System Service
Tools (SST) in the iSeries Service Functions
v If you cannot enter a command at the console, perform an IPL to DST (see Performing an IPL to
DST in the iSeries Service Functions
v If you cannot perform a type A or B IPL, perform a type D IPL from removable media.
3. Did you perform a D IPL to get to DST?
v No: Access the Product Activity Log and display the SRC that sent you here and view the
"Additional Information" to record the formatted log information. Record all the information.
Note: There may be more than one Product Activity Log entry with the same Log ID. Access any
additional entries by pressing the Enter key from the "Display Detail Report for Resource" screen.
View the "Additional Information" for each entry to record the formatted log information. Example:
There may be an xxxx902F SRC entry in the Product Activity Log if there are more than 10 disk
units in the array.
Continue with the next step.
v Yes: A formatted display of hexadecimal information for Product Activity Log entries is not available.
In order to interpret the hexadecimal information, see More Information from Hexadecimal Reports in
the iSeries Service Functions
Note: There may be an xxxx902F SRC entry in the Product Activity Log if there are more than 10
disk units in the array. In order to interpret the hexadecimal information for these additional disk
units, see More Information from Hexadecimal Reports in the iSeries Service Functions
Continue with the next step.
4. Ask your next level of support for assistance.
Note: Your next level of support may require the error information you recorded in the previous step.
This ends the procedure.
SDIOP-PIP23: For use by authorized service providers.
You were sent to this procedure from a unit reference code (URC) 9050. If the failing item is in a migrated
tower, use the Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the V5R1
Supplemental Manuals web site
assistance.
SDIOP-PIP25: For use by authorized service providers.
Use this procedure to isolate the problem when a device attached to the I/O card has functions that are
not given support on the I/O card.
202
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
information).
information).
. Record all the information.
to fix the problem. Otherwise, contact your next level of support for
.

Advertisement

Table of Contents
loading

Table of Contents