Rmdev; Siadpcd - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

System reference code
B448 xB34
B448 xB35
B448 xB36
B448 xB37
B448 xBF0
B448 xBF1
B448 xBF2
B448 xBF3
B448 xBF4
B448 xBF5
B448 xBF6
B448 xBF7
B448 xBF8
B448 xBF9
B448 xBFA
B448 xBFB
B448 xBFC
B448 xBFD
This ends the procedure.

RMDEV

For use by authorized service providers.
A removable media power regulator or device in a migrated expansion tower may be failing.
See the RMDEV symbolic FRU in the Migrated Expansion Tower Problem Analysis, Repair and Parts
manual on the V5R1 Supplemental Manuals web site

SIADPCD

For use by authorized service providers.
SIADPCD: High Speed Link I/O bridge card.
If you are working on a Model 170, 250, 5xx, 6xx, or SBx, see the following for field replaceable unit
(FRU) isolation and repair.
v FI00065 (See page 250)
v AJDG30 software load
The failing component is the HSL I/O bridge card in a system unit primary I/O unit (for Models 830, 840,
870, 890, SB2, and SB3), an FC 5074, FC 5078, FC 0578, FC 5079 (1.8m expansion tower) I/O
expansion tower, or the Integrated xSeries Adapter Card in an xSeries server.
1. If you are working from the Service Action Log and you know the frame ID where this failing
component is located, then continue with the next step in this procedure. Otherwise, record the bus
number value (BBBB) in word 7 of the SRC (see "Breaking down the SRC" on page 63 for help in
determining the bus number). Search for the bus number in HSM or the System Configuration Listing
to determine which frame or I/O tower contains the failing component.
446
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
Location of failure
M39 port C0
M39 port C1
M39 port D0
M39 port D1
M41 ports A0-A1
M41 ports B0-B1
M40 ports A0-A1
M40 ports B0-B1
M30 ports C0-C1
M30 ports D0-D1
M39 ports A0-A1
M39 ports B0-B1
M40 ports C0-C1
M40 ports D0-D1
M30 ports A0-A1
M30 ports B0-B1
M39 ports C0-C1
M39 ports D0-D1
for FRU isolation instructions.

Advertisement

Table of Contents
loading

Table of Contents