Replace the following FRUs in order one at a time until the problem is resolved. Be sure to IPL in
SLOW OVERRIDE mode after each replacement.
a. Processor card in location M03
b. Power supply in location P01
c. Power supply in location P02
d. Power supply in location P03
e. Memory riser card in location M01
f. Memory riser card in location M02
g. System unit backplane in location MB1
This ends the procedure.
6. See Locations — Model 825.
Replace the following FRUs in order one at a time until the problem is resolved. Be sure to IPL in
SLOW OVERRIDE mode after each replacement.
a. Processor card in location M01
b. Processor card in location M02
c. Power supply in location P01
d. Power supply in location P02
e. System backplane extender MB1
f. System backplane extender MB2
g. System unit backplane in location CB1
This ends the procedure.
7. See Locations — Models 830, SB2 system unit with FC 9074 base I/O tower.
Replace the following FRUs in order one at a time until the problem is resolved. Be sure to IPL in
SLOW OVERRIDE mode after each replacement. See Remove and replace procedures.
a. Clock card in location M06A
b. Network interface controller (NIC) card in location M06
c. Processor regulator card in location M01
d. Processor card in location M03
e. Processor card in location M04
f. Power supply in location PP1
g. Power supply in location PP2
h. System unit backplane in location MB1
i. Memory riser card in location M02
j. Memory riser card in location M05
This ends the procedure.
8. See Locations — Models 840, SB3 system unit with processor tower and FC 9079 base I/O tower.
Replace the following FRUs in order one at a time until the problem is resolved. Be sure to IPL in
SLOW OVERRIDE mode after each replacement. See Remove and replace procedures.
a. Clock card in location M19
b. Regulator card in location M04
c. Regulator card in location M07
d. Network interface controller (NIC) card in location M17
e. Processor card 3 in location M16
f. Processor card 1 in location M18
g. Processor card 2 in location M06
h. Processor card 0 in location M05