Table 13. For FC 5078, FC 0578, FC 5088, or FC 0588 I/O frame
Unit reference code
7610, 7611
7620, 7621
7630, 7631
7640, 7641
Table 14. For FC 5095
Unit reference code
7610, 7611
7620, 7621
7630, 7631
7640, 7641
This ends the procedure.

AJDGP01

Licensed Internal Code is the failing item. Look for PTFs associated with the reference code and have the
customer apply them.

ALTINTF

For use by authorized service providers.
The failing item is any card, cable or card enclosure connected to Bus 1 that might cause an interface
failure between the service processor and the alternate IPL load-source device.
1. Check the load source device unit to ensure it is ready.
2. Verify that the load source media (tape or compact disk) is loaded properly and is a valid IPL media.
3. Power off the system from the control panel.
4. Perform the following:
a. Check cable connections:
v For Models 270 and 820, check the cables and connections between the system unit
backplane and the storage device units.
v For Models 830, 840, SB2, and SB3, check the cables and connections between the system
unit and the base I/O tower.
b. Reseat cables where possible.
c. Change the IPL mode to Manual, and the IPL speed to SLOW OVERRIDES using control panel
function 2.
d. Power on the system.
Does the same SRC occur?
274
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
FRU
1. AMD B02
2. Cable (part 51L5652)
3. AMD controller card BB1
1. AMD B02
2. Cable (part 51L5652)
3. AMD controller card BB1
1. AMD B01
2. Cable (part 51L5652)
3. AMD controller card BB1
1. AMD B01
2. Cable (part 51L5652)
3. AMD controller card BB1
FRU
AMD B01
AMD B02
AMD B03
AMD B04

Advertisement