IBM iSeries Series Hardware Problem Analysis And Isolation page 477

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

Follow the instructions for the model you are working on:
v Models 270 and 820 (See page 465)
v Models 800, 810, 825, 830, 840, 870, 890, SB2, and SB3 (See page 466)
Instructions for Models 270 and 820
1. Choose one of the following:
v If you are working on a Model 820, use Table 1. below to determine the service information.
This ends the procedure.
v If you are working on a Model 270, continue with the next step.
2. Is function 20 available on the system unit control panel?
v No: Continue with the next step.
v Yes: Select function 20 on the system unit control panel. Record the processor feature code
(characters 5 through 8). Use Table 1. below to determine the service information.
This ends the procedure.
3. The system unit backplane is in position MB1. To determine which system unit backplane is installed,
remove the cover on the left side. See Models 270, 800, 810 - Covers. Then, continue with the next
step.
4. Examine the card positions on the system unit backplane.
v If there are card positions labeled M01 and M02, then you are working on a Model 270 with a
Network Interface Controller (NIC) embedded in the processor card.
v If there are no card positions labeled M01 and M02, then you are working on a Model 270 with a
Network Interface Controller (NIC) embedded in the system unit backplane.
Table 1. Service information for Models 270 and 820
System model
Model 270
Model 820
FC 5065, FC 5066
FC 5074, FC 5079
FC 5075
Name of FRU to exchange FRU position
System unit backplane
System unit backplane
Expansion unit backplane
Expansion unit backplane
Expansion unit backplane
MB1
MB1
CB1
CB1
CB1
Link to failing component
service information (CCIN,
locations diagram,
remove and replace
procedure)
Go to Locations - Model
270 and follow links for
either the processor feature
code or what FRU the NIC
is embedded in. (The
processor feature code is
characters 5 through 8 of
function 20 on the control
panel.)
See Locations - Model 820.
See Locations - FC 5074
Expansion I/O Tower.
Note: Position CB1 is the
same on the FC 5074, FC
5065, and FC 5066.
See Locations - FC 5074
Expansion I/O Tower or
Locations - FC 5079
Expansion I/O Tower.
See Locations - FC 5075
Expansion I/O Tower.
Analyze hardware problems
465