v Yes: The regulator installed in this step is the failing item.
This ends the procedure.
13. Have you installed all of the regulators that were removed in step 2 (See page 295)?
v Yes: This ends the procedure.
v No: Repeat step 12 (See page 296).

BUSVPD

For use by authorized service providers.
This is a PCI bus VPD at the Multi-Adapter Bridge of the Primary PCI Bus.
1. Choose from the following options:
v If you are working from the Service Action Log, and a card position is listed with this failing item,
then that is where the error is located. Continue with the next step.
v Otherwise, record the bus number value, BBBB, in word 7 of the SRC, see "Breaking down the
SRC" on page 63 (in the Bus PIP Overview section) for help in determining the bus number. Search
for the bus number in HSM or the System Configuration Listing to determine which frame or I/O
tower contains the failing item. Record the frame or tower type. Then, continue with the next step.
2. Use the following table to determine which symbolic FRU to go to the system or tower you are working
on.
System frame or I/O Tower type containing the failing
item
Models 800 and 810
Model 825
Models 870 or 890 Base I/O Tower
FC 5074, FC 5078, FC 0578, FC 5079, or FC 5095
Expansion I/O Tower, FC 5088, FC 0588 Expansion I/O Unit
FC 5075 Expansion I/O Tower
External xSeries Server
This ends the procedure.

CACHBAT

For use by authorized service providers.
The cache battery pack may be failing. Use the cache battery pack location information in the Service
Action Log if it is available. If the location is not available, find the address of the storage IOA. See SRC
address formats. Use the address to find the location. See Locations and addresses.
If the failing item is in a migration tower, go to the CACHBAT symbolic FRU in the Migrated Expansion
Tower Problem Analysis, Repair and Parts manual on the V5R1 Supplemental Manuals web site
Using the type number of the storage IOA, go to Type, model, and part number list to determine the cache
battery pack part number.
To exchange the cache battery pack, see Type 2748, 2757, 2763, 2778, 2780, 2782, 5703, 5708 - Cache
battery pack.

CACHE

For use by authorized service providers.
Action
Go to symbolic FRU "SYSBKPL" on page 464
Go to symbolic FRU "SYSBKPL" on page 464
Go to symbolic FRU "TWRPLNR" on page 473
Go to symbolic FRU "TWRPLNR" on page 473
Go to symbolic FRU "TWRBKPL" on page 469
Go to symbolic FRU "SIADPCD" on page 446
Analyze hardware problems
.
297