CPYSCEN or CSD
Copies the data for the scene with the number specified with command argument 1 to the scene with
the number specified with command argument 2. If there is already data at the copy destination, the
copied data is written over that data.
<Command format>
C P Y S C E N E
or
C S D
<Response format>
When processing is performed normally:
When processing is not performed normally:
<Parameters explanation>
Copy destination
scene No.
Copy destination
scene No.
(Example)
Copying the scene data for Scene 2 to Scene 10:
<Command>
<Response>
DATALOGCOND or DLC
Getting the data logging condition
A - 88
C
R
Copy destination scene No. (3 digits max.)
Copy source scene No. (3 digits max.)
C
R
Copy destination scene No. (3 digits max.)
Copy source scene No. (3 digits max.)
Specifies the scene No. to copy from (0 to the number of scenes in the scene group − 1).
Specifies the scene No. to copy to (0 to the number of scenes in the scene group − 1).