2 Methods for Connecting and Communicating with External Devices
Preferred WINS server
Alternate WINS server
4
Click Apply to finish the settings.
Click Close to close the System Settings dialog.
Precautions for Correct Use
Change the IP address and subnet mask for [Address setting] and [Address setting 2] as re-
quired so that each designate a different network address. If the same network address is
specified, communications may not be performed correctly.
Setting the EtherNet/IP Output Specifications
1
On the Main window, click Tool - System Settings to open the system settings.
2
Select System Settings → Communication → EtherNet/IP.
The Ethernet view is displayed.
3
Set each item.
2 - 204
Setting item
[Factory default]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[0.0.0.0]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[0.0.0.0]
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
Setting value
Enter the WINS server address.
Enter the WINS server address.
Description