l Continuous Measurement Command (Without handshaking)
Continuous execution is used to repeatedly execute measurement by starting the next measure-
ment operation (image input and measurement processing) as soon as single measurement opera-
tion (image input and measurement processing) is completed.
Continuous measurement is started when the Start Continuous Measurements command is exe-
cuted and ended when the End Continuous Measurements command is executed.
Command
Command Parameter
Area
Response
Area
Command Completion
*1: A timeout error will occur if you do not turn off the Command Execution (EXE) signal within 10
seconds after the Command Completion (FLG) signal is turned ON.
Command Completion (FLG) signal and BUSY signal will be forcefully turned OFF.
*2: Busy (BUSY) signal is automatically switched ON to OFF when the command execution is completed.
<Operation to Start Continuous Measurements>
(1)
The PLC (user) sets the Start Continuous Measurements command code.
(2)
After checking that the BUSY signal and the Command Completion (FLG) signal have turned OFF, the
PLC turns ON the Command Request (EXE) signal again to instruct the Sensor Controller to perform
it.
(3)
When completing the preparations for continuous measurement, the Sensor Controller sets the com-
mand code and response code. when preparations for continuous measurement have been complet-
ed.
(4)
The Command Completion (FLG) signal is turned ON.
(5)
The PLC (user) turns OFF the Command Request (EXE) signal when the Command Completion
(FLG) signal turns ON.
(6)
After detecting that the Command Request (EXE) signal has turned OFF, the Sensor Controller starts
continuous measurement and turns ON the BUSY signal.
(7)
The Command Completion (FLG) signal is automatically turned OFF.
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
ON
Command Code
OFF
ON
OFF
ON
Command Execute
(EXE) signal
OFF
ON
Command Code
OFF
ON
Busy
(BUSY) signal
OFF
ON
Response Code
OFF
ON
(FLG) signal
OFF
ON
overall Judgement
(OR) signal
OFF
(1)
Start Command for Continuous Measurement
*1
Control command is running.
Preparation for continuous
measurement is initialed.
(2)
(3)
(4)(6)
End Command
for Continuous Measurement
(5)
(12)
*1
Timeout
Timeout
*2
Measuring
Measuring
(13)
(7)
(8)
(9)
(10) (11)
2
2 - 307