Omron SYSMAC FH Series User Manual page 445

For communication settings
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Signal
GATE
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
Signal name
Function
Data Output
This signal indicates the
Completion
timing to load the output
signal
data from DO0 to DO15
to the User (PLC Link).
This signal is ON, which
means that the data is
output from the Sensor
Controller.
The user (PLC) reads
the data when this sig-
nal turns ON.
Depending on the
measurement flow set-
tings, the GATE output
may start while the
BUSY signal is ON.
Note that the OR signal
does not necessarily
work together with the
GATE signal.
ON/OFF timing
OFF to ON
No Handshaking:
Turn ON when the
Sensor Controller of
the FH/FHV series
executes the Output
Unit (Parallel Data
Output Unit or Paral-
lel Judgement Output
Unit) in the measure-
*1
ment flow
and
preparations for data
output have been
completed.
Handshaking:
Turn ON when the
Sensor Controller of
the FH/FHV series
executes the Output
Unit (Parallel Data
Output Unit or Paral-
lel Judgement Output
Unit) in the
measurement
*1*2
flow
, the Data
Output Request
(DSA) signal is ON,
and preparations for
data output have
been completed.
*1: This occurs when
the Output Unit is
executed as the
measurement flow is
executed in order
from the top. It does
not occur when exe-
cution of a measure-
ment is completed.
*2: The signal is out-
put if a Parallel
Judgement Output
or Parallel Data
Output processing
item is set in the
measurement flow.
ON to OFF
No Handshaking:
The signal turns OFF
after the set output
time has elapsed.
Handshaking:
The signal turns OFF
when the user (PLC)
turns OFF Data Out-
put Request (DSA)
2
signal.
2 - 383