Asynchronous Output
Retry interval [ms]
Retry Interval 2 [ms]
Polling Cycle [ms]
*1.
In the communications using Handshaking, a timeout error will also occur if any of the following op-
erations were not performed within the time set this Retry interval as well..
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
Setting item
[Factory default]
Selected
*2
[Not selected]
0 to 999999
[10000]
0 to 999999
[10000]
-1 to 999999
[0]
Setting value
Selected:
Measurement processing and data output
processing are performed in parallel.
The data output processing does not affect
the processing time of the measurement
flow.
[Not selected]
Measurement processing and data output
processing are synchronized so that all data
output processing is completed at the meas-
urement end.
This increases the overall processing time
for the measurement flow.
For details, refer to Asynchronous Output on
page 2 - 152.
Set the time until when a timeout error will
occur because the PLC Link communications
are not established with incorrect communi-
cation settings or communication cables bro-
*1
ken.
After a timeout error occurred, communica-
tions with the destination device will be at-
tempted with the interval time set in the Retry
interval.
For details, refer to Data Output Control with
Handshaking on page 1 - 25.
When the PLC Link communications fail due
to a temporary response delay affected by
heavy network loads and the PLC internal
status, the command will be re-transmitted to
the destination device after the time set in
the Retry Interval 2 passed.
Set the shorter time in the Retry Interval 2
than that in the Retry Interval.
Normally use the default values.
-1:
When this value is set, polling will not be per-
formed in normal operation. This setting
eliminates influence to measurement proc-
essing time due to communications (polling)
in normal operation. Although commands will
not be performed, data output and flow con-
trol can be performed.
0 to 999999:
Set the interval at which the Sensor Control-
ler of the FH/FHV series checks that the
Command Execute (EXE) signal from an ex-
ternal device such as PLC, switches from
OFF to ON.
Description
2 - 139
2