Omron SYSMAC FH Series User Manual page 45

For communication settings
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Settings Required for Data Output
Use the following procedures to set up Output Unit for data output.
● Measurement Data
(1) Place the data output processing unit(s) in the processing flow.
Place the processing unit for data output in the measurement flow.
Processing Units That Serve as Output Units:
On the processing item tree in the Flow Editor window, the processing items under Output result
serve as Output Units.
Output Unit Selection:
Select the Output Units with the following combination according to a communication protocol to
be used.
For details of communication protocols, refer to 1-3-4 Communication Protocols for Communicat-
ing with the Sensor Controller on page 1 - 9.
Output unit
Result Output (I/O)
Result Output (Message)
Result Output (Parallel
I/O)
Parallel Data Output
Parallel Judgment Output
Serial Data Output
Fieldbus Data Output
*1.
Except message communications
Precautions for Correct Use
When Non-procedure UDP is used to output data of Result output (Message), the Sensor Con-
troller outputs the data to only the device whose command was accepted in the end.
(2) Set the items to output
Set the items to output as output data in the Output Units placed in the measurement flow.
For the procedures to set output items in the Output Units, refer to the description for each com-
munication protocol.
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
OK: Data can be output, - : Data cannot be output.
Communication Protocol
Paral-
PLC
EtherNet/IP
lel
Link
-
OK
*1
OK
-
-
-
-
OK
*1
OK
OK
-
-
OK
-
-
-
OK
-
-
-
OK
1 Overview
EtherCAT
PROFINET
OK
OK
-
-
OK
OK
-
-
-
-
-
-
OK
OK
1
Non-
procedure
-
OK
-
-
-
OK
-
1 - 21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents