First word in
Response
Area
+6
+7
+8
+9
:
:
*1.
Regarding the storage destination folder
The storage destination folder differ according to the Sensor Controller series.
FH series/FHV series
RAM disk: C:\Data\RAMDisk
External storage device: E:\, F:\
Do not save to any folder except RAMDisk and external storage device (such as C:\ProgramFiles\FZ).
It is possible not to perform correctly due to the decrease of Scene data storage region.
Get Image Logging Folder Name
Gets the image logging folder name.
Command (PLC to Sensor Controller)
First word in
Command
Area
+2
+3
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
Command
code
15 - 12
-
0000
-
0000
-
0000
-
0000
-
0000
-
0000
Command
code
15 - 12
4010
0100
0040
0000
Bit
11 - 8
7 - 4
3 - 0
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
11 - 8
7 - 4
3 - 0
0000
0001
0000
0000
0100
0000
Appendices
Description
[Identifier 0] [Identifier 1]
[Identifier 0]: Logging
[Identifier 1]: Identifier of setting
to get
For imageLogging (image
log):
0 (will not save), 1 (save
when NG), 2 (save all)
For imageLoggingDirectory
(image log saving
destination folder name):
Destination folder name
(half-width alphanumeric)
For imageLoggingHeader
(prefix of image logfile
name):
Prefix of image log file name
(halfwidth alphanumeric)
For dataLogging (data log-
ging):
0 (will not save), 1 (save
when NG), 2 (save all)
For dataLoggingDirectory:
saving destination folder
name (half-width alphanu-
meric)
Description