Appendices
<Response>
SGRLOAD
Loads scene group data.
<Command format>
<Response format>
When processing is performed normally:
When processing is not performed normally:
<Parameters explanation>
Scene group No.
File name of Scene group data
Precautions for Correct Use
Do not turn off the power to the Sensor Controller until there is a response.
(Example)
When you load the following case:
• Scene group number: 3
• SCNLOAD file name: LABEL1.SGP
• Drive name: USBDisk2
• Folder name of the external storage: IMG01
A - 158
\
\
\
Specifies the scene group No. to be loaded (0 to 31)
The name of the file containing the Scene group data you wish to load.
Specify the file name as an absolute path.
The file name needs the "SGP" extension.
The file which has "SGP" extension can be load.
The load destination to use differs by Sensor Controller model.
Load destination
RAMDisk
External storage
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
FH series/FHV series
C:\Data\RAMDisk
E:\, F:\, G:\, H:\, M:\