l Output Control: Synchronization Control
Operation When Number of Delays Is Set to 2:
ON
STEP signal
OFF
ON
BUSY signal
OFF
OR signal
DO signal
ON
GATE signal
OFF
(1)
Turn ON the STEP signal while the BUSY signal is OFF.
(2)
The Overall Judgment (OR) signal is output when BUSY signal switched from ON to OFF.
(3)
When the STEP signal turns ON for the third time, the measurement results (DO) for the first time that
the STEP signal turned ON are output and the GATE signal is turned ON after the time set for the
GATE ON delay has elapsed.
(4)
When the STEP signal turns ON for the fourth time, the measurement results (DO) for the second time
that the STEP signal turned ON are output and the GATE signal is turned ON after the time set for the
GATE ON delay has elapsed.
A delay of up to 1 [ms] will occur when the GATE signal is turned ON. (This applied only to the FH.)
(5)
Each time the STEP signal turns ON after that, the measurement result (DO) from when the STEP
signal turned ON two times previously is output.
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
The signal is turned OFF when the BUSY signal turns ON.
(1)
(2)
ON while measurements are being processed
Overall judgement
Overall judgement
result for (1)
(Result not
output.)
Delay time
(1 ms max.)
(3)
(4)
(5)
Overall judgement
Overall judgement
result for (2)
result for (3)
result for (4)
The results for (1) is output when the STEP signal
turns ON the third time.
Result for (1)
Result for (2)
Result for (3)
GATE ON delay
Output time
Overall judgement
result for (5)
Result for (4)
2 - 401