Connecting via RS-232C
Additional Information
• Input signals cannot be handled during setting of communications specifications. However,
the input status can be checked with Confirmation.
For details, refer to 2-5-7 Testing Communications on page 2 - 338.
• Data output via serial communications is suspended while communications specifications are
being set.
1
On the Main window, click Tool - System Settings to open the system settings.
2
From the tree view on the left, select System Settings and then select Communication
−RS-232C/422 (Normal) or RS-232C/422 (Normal (Fxxx series method))
The RS-232C window is displayed.
3
Set each item..
Setting item
Interface
Baud rate [bps]
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
Set value
[Factory default]
[RS-232C]
*1
RS-422
2400
4800
9600
*2
19200
[38400]
57600
115200
Description
Align the communication specifications with the external de-
vice.
Align the communication specifications with the external de-
vice.
2
2 - 323