For communication settings
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

2 Methods for Connecting and Communicating with External Devices
Input and Output settings
Output IP Address/TCP
Server
Input/Output port No.
*1.
When the TCP is used for the connection, TCP Server is displayed. Factory default settings are
[10.5.5.101].
*2.
When the TCP is used for the connection, Factory default settings are [9876].
Precautions for Correct Use
• If the operation mode is set to Multi-line Random-trigger Mode, set a different I/O port num-
ber for each line.
• Change the IP address and subnet mask for Address setting and Address setting 2 as re-
quired so that each designate a different network address. If the same network address were
specified, communications may not be performed correctly.
• Be sure to change the output IP address from its factory default value in accordance with
your network environment.
3
Click PLC Link.
The PLC Link view is displayed.
4
Set the following items.
Some setting items vary depending on the selected communication module.
2 - 136
Setting item
[Factory default]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
*1
d: 0 to 254
[0.0.0.0] /
[10.5.5.101]
0 to 65535
[9600] / [9876]
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
Setting value
Enter the IP address for the output destina-
tion.
*1
Set the port number to use for the data input
*2
and output with the Sensor Controller.
Description