Omron SYSMAC FH Series User Manual page 642

For communication settings
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Appendices
Additional Information
To set a character string which includes spaces, enclose the character string with " ".
Example:
Setting the character string to compare (value of the external reference table No. 164 value) as
"ABC EFG" of the second processing unit (Processing unit No.1).
UNITDATA 1 164 "ABC EFG"
UPDATEMODEL or UMD
Re-registers a model using the current image.
<Command format>
U P D A T E M O D E L
or
U M D
<Response format>
When processing is performed normally:
When processing is not performed normally:
<Parameters explanation>
Processing unit No.
Model No.
A - 170
C
R
Target data (1 digit)
Model No.
Processing unit No.
Specifies the processing unit number of a model to re-register: 0 to the number of
unit items − 1.
Specifies the model number to register a model: 0 to the uppermost unit model num-
ber in the unit.
Specifying a nonexistent model number causes an error.
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
C
R
Target data (1 digit)
Model No.
Processing unit No.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents