Omron SYSMAC FH Series User Manual page 205

For communication settings
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Communicating with a Yaskawa Electric PLC
(When PLC Link (JEPMC MP) is selected for the Communication module.)
Command Area
Areas
Address
Response Areas
Areas
Address
Data Output Area
Areas
Address
Output Control
Asynchronous Output
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
Setting item
[Factory default]
Data register
0 to 99999
[0]
Data register
0 to 99999
[100]
Data register
0 to 99999
[200]
Setting item
[Factory default]
None
[Handshaking]
Selected
*2
[Not selected]
Setting value
The Command Area is fixed to the Data reg-
ister.
Set the first channel address of the Com-
mand Area.
The Response Area is fixed to the Data reg-
ister.
Set the first channel address of the Re-
sponse Area.
The Data Output Area is fixed to the Data
register.
Set the first channel address of the Data
Output Area.
Setting value
Set whether to provide an interlock with the
PLC when the data is performed.
None: Data is output regardless of the status
for signals from he PLC. The GATE is always
OFF.
Handshaking: Data is output after the DSA
signal from the PLC was checked.
Selected:
Measurement processing and data output
processing are performed in parallel.
The data output processing does not affect
the processing time of the measurement
flow.
[Not selected]
Measurement processing and data output
processing are synchronized so that all data
output processing is completed at the meas-
urement end.
This increases the overall processing time
for the measurement flow.
For details, refer to Asynchronous Output on
page 2 - 152.
Description
Description
2 - 143
2