Service
Service code
14 (0E Hex)
16 (10 Hex)
• Settings for Data Sent by the Sensor Controller
Instance
Setting item
Instance
Attribute
Attribute ID
0x03
0x04
Service
Service code
14 (0E Hex)
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
Name
GetAttributeSingle
SetAttributeSingle
Setting val-
ue
101
For normal control and for line 0 in Multi-line Random-trigger Mode
103
For line 1 in Multi-line Random-trigger Mode
105
For line 2 in Multi-line Random-trigger Mode
107
For line 3 in Multi-line Random-trigger Mode
109
For line 4 in Multi-line Random-trigger Mode
111
For line 5 in Multi-line Random-trigger Mode
113
For line 6 in Multi-line Random-trigger Mode
115
For line 7 in Multi-line Random-trigger Mode
Access
Name
Get
Data
Get
Size
Name
GetAttributeSingle
Description
This attribute gets the attribute value.
This attribute sets a value for the attribute. Whether an attribute
can be set depends on the access attribute of it.
Description
Data type
This attribute sets the data sent by the Sen-
sor Controller
The format is the same as an input connec-
BYTE array
tion in tag data link communications.
For details, refer toOutput Connection to PLC
(Sensor Controller (Originator) to PLC
(Target)) on page 2 - 228.
UNIT
Number of bytes: 48
This attribute gets the attribute value.
Description
Description
2 - 257