Omron SYSMAC FH Series User Manual page 546

For communication settings
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Appendices
Set Parallel Terminal Offset
Sets the parallel DI terminal offset data.
The parallel DI terminal offset is the value that is added from the DI0 to DI4 command parameter when
a parallel command is executed.
This is useful in the following cases.
Example:
This example is for creating a custom communications command for parallel communications that sets
a numeric value using from DI0 to DI6.
• Without an Offset:
You can set only values between the minimum value of 0 and the maximum value of 127 (0111 1111
binary).
• With an Offset:
Adding an offset of 100 allows you to specify numeric values from a minimum value of 100 to a max-
imum value of 227 (127 + 100) by specifying the same values as those used without offsets.
Command (PLC to Sensor Controller)
First word in
Command
Area
+2
+3
+4
+5
Response (Sensor Controller to PLC)
First word in
Response
Area
+2
+3
+4
+5
A - 74
Command
code
15 - 12
4060
0100
0050
0000
-
0000
-
0000
Com-
mand
15 - 12
11 - 8
code
4060
0100
0000
0050
0000
0000
-
0000
0000
-
0000
0000
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
Bit
11 - 8
7 - 4
3 - 0
0000
0110
0000
0000
0101
0000
0000
0000
0000
0000
0000
0000
Bit
7 - 4
3 - 0
0110
0000
0101
0000
0000
0000
0000
0000
Description
Command code
Parallel DI terminal offset data
0 to 9999
Description
Command code
Response target command codes
Response code
Command execution result
OK: 0 (0000 0000)
NG: Not 0 (0000 0000)