2 Methods for Connecting and Communicating with External Devices
l Checking the Communication Status
Use the ping command to check whether or not the Sensor Controller exists on the Ethernet net-
work.
With it, check that the Sensor Controller IP address has been correctly set and is correctly connect-
ed to the Ethernet network.
Additional Information
The ping command uses the ICMP protocol to send a response request to a device connected
through an Ethernet network and determines the time required to respond to that request.
If you properly receive a response from the destination device, the network connection and net-
work settings are correctly set.
1
Connect the Sensor Controller and a computer with an Ethernet cable.
Set the high-order digits of the computer IP address to the same values as the Sensor Control-
ler and the low-order one digit to a different value.
<IP Address Setting Example>
Sensor Controller
Computer
2
Open the Windows command prompt on the computer and perform the ping command.
At the > prompt, type ping, followed by a space and the Sensor Controller IP address, and then
press Enter.
Example:
C:\>ping 10.5.5.100
3
After a few seconds, Reply from followed by the IP address of the Sensor Controller (e.g.,
10.5.5.100) are displayed, it means that the Sensor Controller is connected to the Ethernet net-
work properly.
2 - 166
5. Click the [PLC Link settings] tab.
6. Set the area settings.
Match these settings with those on
the destination PLC.
7. Set the output control.
Set whether to provide an interlock with
the PLC when performing data output.
8. This completes the Controller settings.
Device
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
Example
10.5.5.100 (default)
10.5.5.101