2 Methods for Connecting and Communicating with External Devices
Additional Information
If you delete one of the expressions that is set for output data 0 through 7, the output numbers
for all expressions after the deleted expression will stay the same. However, the actual data
output will be output as though the list has been shifted forward for the number of expressions
that have been deleted.
To prevent data from being written to the wrong locations, use copy and paste to shift the ex-
pressions after the deleted number forward.
For details of the Data Output Area, refer to 2-3-12 Memory Allocation on page 2 - 227.
Example: If the Expression for Output 1 Is Deleted
Output Item Settings
Output Item Settings
2 - 216
Output 1 is deleted.
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
Data Output Destination (Data Output Area)
Bit
First word
15
+8
DATA1 (Reference SX)
+9
+10
DATA2 (Reference SY)
+11
+12
DATA3 (Reference angle ST)
+13
Data Output Destination (Data Output Area)
Bit
First word
15
+8
DATA1 (Reference SX)
+9
+10
DATA3 (Reference angle ST)
+11
+12
+13
The output numbers assigned to the
expressions remain the same, but the data
output location is shifted forward for data 3.
to
0
to
0