2 Methods for Connecting and Communicating with External Devices
Data type
BOOL
SINT
INT
DINT
USINT
UINT
UDINT
BYTE
WORD
DWORD
REAL
Additional Information
All values are stored in little Indian order.
Class ID: 4 Assembly Object
This object is used to communicate with a PLC that does not support tag data link communications.
• Settings for Data Received by the Sensor Controller
Instance
Setting item
Instance
Attribute
Attribute
ID
0x03
Set
0x04
Get
2 - 256
Description
Boolean
Short integer
Integer
Double-precision integer
Unsigned short integer
Unsigned integer
Unsigned double-precision integer
Bit string: 8 bits
Bit string: 16 bits
Bit string: 32 bits
Floating-point real
Setting value
100
For normal control and for line 0 in Multi-line Random-trigger Mode
102
For line 1 in Multi-line Random-trigger Mode
104
For line 2 in Multi-line Random-trigger Mode
106
For line 3 in Multi-line Random-trigger Mode
108
For line 4 in Multi-line Random-trigger Mode
110
For line 5 in Multi-line Random-trigger Mode
112
For line 6 in Multi-line Random-trigger Mode
114
For line 7 in Multi-line Random-trigger Mode
Access
Name
Data type
BYTE ar-
Data
ray
Size
UNIT
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
Min. value
0: FALSE
-128
-32768
31
-2
0
0
0
-
-
-
Single-precision floating-point range
Description
Description
This sets the command received by the Sensor Controller.
The format is the same as an output connection in tag data
link communications. For details, refer toInput Connection
to the Sensor Controller (PLC (Originator) to Sensor
Controller (Target)) on page 2 - 227.
Number of bytes: 20
Range
Max. value
1: TRUE
127
32767
31
2
- 1
255
65535
32
2
- 1
-
-
-