Omron SYSMAC FH Series User Manual page 355

For communication settings
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Set the first
channel in
Command
Area.
+22
+23
+24
+25
EXE
DSA
STEP
XEXE
ERCLR
CMD-CODE
CMD-PARAM
User Input Area 0 to 5
FH/FHV Series Vision System User's manual for Communication Settings (Z342-E1)
2 Methods for Connecting and Communicating with External Devices
15
14
13
12
11
10
User Input Area 5
Signal
Command Execution Bit
Data Output Request Bit
Measure Bit
Flow Command Request Bit
Error Clear Bit
Command Code
Command parameters
User Input Area 0 5
Bit
9
8
7
6
5
4
Signal name
Performs a command. For details,
refer to2-4-14 Command List on
page 2 - 303.
Requests the next data output.
For details, refer to2-4-8 Output
Data Settings (Processing Item
Registration) on page 2 - 278.
Performs measurement one time.
Instructs a command execution
during the execution of the Field-
bus flow control.
Clears the ERR signal from the
Sensor Controller.
Stores the command code.
Stores the command parameters.
This area is used that you write
the data that you defined for the
Sensor Controller.
Name
3
2
1
0
User Input
Area 5
Function
Data type of User Input Area 0
to 3 is DINT. Data type of User
Input Area 4 to 5 is LREAL.
2 - 293
2

Hide quick links:

Advertisement

Table of Contents
loading