BHT-1200 Series
Ping settings
The Ping settings menu is used to set up the ping command parameters.
Tap the "Settings" button in the ping menu to display the "Ping settings" menu.
Data size:
Interval:
Timeout:
Type1 or Type2:
Count:
Tap the "Default" button to restore the default settings.
Setting ranges
Item
Data size
Interval
Timeout
Type
Count
* When zero (0) is set, the "Count" is set to infinity.
The echo requests are sent until the ping test is aborted.
If the specified value exceeds the value range, the closest value to the range will be automatically set as
the value.
If the "timeout" is set to the value exceeding the range when Type 1 is chosen, the value will be
automatically replaced by the value set as the "interval".
138
Specify the data size of the echo request.
Specify the length of echo request intervals (in 100 ms units).
Specify the timeout period (in 100ms units) for the echo request.
Choose "Type 1" or "Type 2" for timing when to send an echo request (refer to the
next page for details).
Specify the number of echo requests to send.
Value Range
1 to 2048
0 to 65535
0 to 65535
Type1/Type2
0* to 65535
Default Value
32
10
10
Type2
4