[10] G sensor
The G sensor is factory calibrated, so recalibration is not necessary unless the screen
auto-rotation
does not work properly.
The G sensor calibration menu differs depending on the G sensor type mounted on the BHT.
For the G sensor type 2, the maximum number of calibration is set to five times.
For G sensor Type 1
To recalibrate the G sensor, follow the steps below.
1. Place the CU on a flat surface.
2. Set the BHT in the CU.
3. Double tap the "G Sensor" icon in the System Properties.
4. Tap the "Recalibrate" button to start recalibration.
Recalibration takes about 10 seconds to finish.
Do not remove the BHT from the CU while calibrating.
The popup message is displayed when the recalibration is successfully
completed.
The popup error message is displayed if the recalibration failed,
in this case, retry.
For G sensor Type 2
To recalibrate the G sensor, follow the steps below.
1. Place the CU on a flat surface.
2. Set the BHT in the CU.
3. Double tap the "G sensor" icon in the System Properties.
4. Tap the "Recalibrate" button.
5. The confirmation popup message is displayed when the
"Recalibrate" button is tapped.
Tap the "Yes" button to start recalibration.
Do not remove the BHT from the CU while calibrating.